Biomedical Image Reconstruction in the Age of AI — Learning Regularisers
Signal processing and biomedical imaging are inseparable: advances in optimisation and machine learning drive faster MRI and CT acquisition, higher-resolution microscopy, and nonlinear reconstruction in phase retrieval. Measurements do not directly form the image and require a reconstruction technique to recover the image from the measurements. This tutorial covers reconstruction methods through three generations, from classical to learned regularisers.
Part one introduces imaging modalities: microscopy, CT and MRI, and formalises reconstruction as an inverse problem, defines the forward operator, its adjoint, and the existence, uniqueness and stability conditions. Part two develops the variational formulation of reconstruction: data fidelity, regularisation and their MAP/MMSE interpretation, the Wiener filter and Tikhonov regularisation; before building the optimisation toolbox for sparsity-driven regularisation: proximal and primal-dual methods.
Part three is the focus of the tutorial: regularisation in the age of AI. Beyond end-to-end learning, deep unfolding and generative priors, it emphasises plug-and-play reconstruction and learning regularisers, including our own recent work, for which the learnt regulariser remains well-defined and (weakly) convex, preserving the convergence and stability guarantees of the second part. It closes with practice, evaluation and open problems, accompanied by code.
Abijith Kamath
Ecole polytechnique federale de Lausanne
Jonathan Dong
Ecole polytechnique federale de Lausanne
Sebastian Neumayer
Technische Universität Chemnitz
Mathews Jacob
University of Virginia
Diffusion Priors with Potentials: Fast Algorithms, Scalable Training, and Guarantees for Large-Scale Image Reconstruction
Reconstructing images from noisy and partial measurements is central to medical and biological imaging. Recovery from imperfect data enables shorter scans, lower dose, and higher spatial and temporal resolution than the acquired data would otherwise support. Learned reconstruction frameworks now show a clear benefit over classical handcrafted priors in Bayesian image recovery. Diffusion and flow models, which rely on image denoisers trained at multiple noise scales, have recently emerged as particularly powerful, because a single learned prior serves many forward operators without retraining. This tutorial introduces recent advances in image recovery using diffusion and flow priors. We give a rigorous account of how these models are guided by data consistency to sample from the posterior distribution, and we discuss the associated challenges and trade-offs. We demonstrate the benefits across a range of high-dimensional applications. We then consider a subclass of diffusion models that carry an explicit potential, analogous to the cost functions of classical optimization, and show that these models yield faster algorithms, improved reconstruction quality, and convergence guarantees. We also cover training strategies for large-scale applications, including high-resolution, dynamic, quantitative and 3D/4D imaging, and training from undersampled noisy measurements.
Physiology in fMRI: Removal, Inference, Signal, Mapping – PRISM
Blood-oxygen-level-dependent (BOLD) fMRI is only indirectly coupled to neuronal activity: a substantial fraction of the measured signal originates in non-neuronal physiology: cardiac and respiratory cycles, systemic low-frequency oscillations, autonomic and vascular dynamics. These contributions are simultaneously a problem (they bias functional connectivity, are subject-specific, correlate with traits, and degrade reliability and reproducibility) and, increasingly, a signal of interest (cerebrovascular reactivity, blood-flow dynamics, autonomic state).
This full-day tutorial covers the complete lifecycle of non-neuronal physiology in fMRI. We begin with the physiological origins of the BOLD signal and why they matter. We then treat physiology as noise to be modeled and removed (RETROICOR, RVT/HRV, response functions; phys2denoise, WHOCARES, rsHRF); as signal to be recovered when recordings are absent (data-driven and deep-learning estimation of cardiac and respiratory signals); and as signal of interest: systemic low-frequency oscillation and time-delay mapping with rapidtide, cerebrovascular reactivity with phys2cvr, a phase-contrast MRI carotid protocol, and autonomic physiology from cortex to brainstem and CSF across arousal states. A closing case study shows how denoising choices propagate to fingerprinting, reliability and behavioural prediction. Live demonstrations use open software and public data throughout.
This important topic for neuroscience and neuroimaging research hasn’t been covered extensively in IEEE events (conferences, journals). Therefore, it is a hot-topic that is relatively new for the IEEE community, opening the doors for brainstorming and collaborations across attendants.
Daniele Marinazzo
Ghent University
Cesar Caballero Gaudes
Basque Center on Cognition, Brain and Language (BCBL), Donostia–San Sebastián, Spain
Laura Belli
Ghent University
Lia Hocke
Basque Center on Cognition, Brain, and Language
Pinar Özbay
Boğaziçi Üniversitesi
Blaise de B Frederick
Harvard Medical School
Stefano Moia
Maastricht University
Giulio Tani Raffaellei
Ghent University
Reliable Medical Image Computing with Conformal Prediction: Opportunities, Limitations, and Advanced Solutions – Acronym: Conf-MIA
Reliable deployment remains a major barrier to translating high-performing medical imaging models into clinical practice. Conformal prediction (CP) offers a compelling framework because it can wrap arbitrary pre-trained models with finite-sample, distribution-free coverage guarantees, producing prediction sets, intervals, or risk-controlled outputs that are directly interpretable at deployment. Yet these guarantees depend on assumptions and calibration regimes that are often challenging in medicine, where annotations are scarce, patient populations are heterogeneous, and deployment distributions can shift.
This tutorial will move beyond introductory inductive CP and will focus on the advanced issues that have recently motivated skepticism and criticism in the medical imaging community. We will examine finite-sample instability under small calibration sets, the gap between marginal and subgroup coverage, and violations of exchangeability under domain shift. We will then present practical solutions: full conformal prediction for data-efficient calibration, subgroup/localized/conditional CP for finer-grained guarantees, and shift detection and weighted CP for non-exchangeable settings.
This tutorial will combine theoretical lectures and hands-on notebooks. Examples will span radiology, histology, ophthalmology, and endoscopy, covering classification, multimodal understanding, and reconstruction/generative tasks. Attendees will leave able to construct, evaluate and adapt conformal predictors for medical imaging deployment, with practical, principled reliability guarantees.
Julio Silva-Rodríguez
ETH Zürich, Switzerland
Adrian Galdran
Ikerbasque, Spain
Reproduce scientific results with the Virtual Imaging Platform
In the last few years, there has been a growing awareness of reproducibility concerns. Everything matters when it comes to improving reproducibility, from the computational environment and software versions, to the tool selection and the more global methodological approach. In this tutorial we focus on a reproducibility level ensuring that an investigator is able to reproduce published results obtained with scientific applications in the field of medical imaging on the Virtual Imaging Platform (VIP).
VIP is a open web portal providing scientific applications as a service. By effectively leveraging the computing and storage resources of the EGI federation, VIP offers its users high-level services enabling them to easily execute medical imaging applications on a large-scale computing infrastructure. VIP also provides advanced functionalities for enhancing open and reproducible science. Our final aim is to provide an integrated, end to end solution, allowing researchers to launch reproducible executions in a transparent manner.
The tutorial will include a short presentation of the VIP functionalities, an overview of current reproducibility issues and best practices, as well as a hands-on session aiming at reproducing results from one of our previous ISBI studies, with a concrete example from the magnetic resonance spectroscopy research community.
Sorina Pop
INSA‐Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294
Hélène Ratiney
INSA‐Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294
Axel Bonnet
INSA‐Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294